Skip to content
Strategic OEM Technology Partner | Princeton Innovation Center, NJ (USA)
ImageProVision Logo

Advanced AI vision.
Deeper analytical insight.

Pioneering AI computer vision, motorized high-magnification microscopy, sub-visible particulate quantification (USP <788> / <789>), automated parenteral vial inspection (VIA), hot stage thermal analysis, and 21 CFR Part 11 compliant image processing software for pharmaceutical QC laboratories. Engineered by ImageProVision Inc. and supported with turnkey local validation (DQ/IQ/OQ/PQ) and GAMP 5 CSV across Egypt by QEEMA.

CLAIRITY™ PARTICLE Automated Particle Characterization System
ImageProVision · CLAIRITY™ Automated Particle Characterization System
21 CFR Part 11 & ALCOA+ Audit Trail Local CSV by QEEMA
11+

Specialized AI & Microscopy Analytical Solutions

100%

21 CFR Part 11 & EU Annex 11 Audit Trail Compliance

0.1 µm

Sub-Micron High-Precision Particle Detection Limit

Turnkey

Egyptian DQ/IQ/OQ/PQ & CSV Local Support by QEEMA

US FDA 21 CFR Part 11 Compliant USP <788> / <789> Particulate Limits Ph. Eur. 2.9.19 Microscopic Method ALCOA+ Data Governance Turnkey Local Validation in Egypt by QEEMA
LABORATORY ANALYTICAL MODALITIES

Explore Solutions by Testing Application

Click any analytical discipline below to instantly filter the certified CLAIRITY™ portfolio and jump to relevant systems.

Particle & Nano
USP <788> sub-visible count, morphology & nano sizing
Hot Stage Thermal
Polymorph phase transitions, melting & crystal kinetics
Vial & Packaging
Visible foreign matter (VIA) & capsule seam integrity
Microbe & Cell
Automated CFU colony counting & cell viability assays
Artwork & AI
Deep learning classification & packaging leaflet audit
DIRECT SYSTEM DEMONSTRATIONS · HOSTED ON QEEMA SERVER

Watch CLAIRITY™ AI Systems in Action

Watch official system demonstrations of ImageProVision's AI microscopy and automated inspection platforms in regulated pharmaceutical operations. Videos are hosted locally on QEEMA's server—no YouTube links, no external ads, and completely cleanroom compliant.

CLAIRITY Demo Video

Click to Play Video on Site

Direct Local Video 1080p MP4
AI-powered pharmaceutical microscopy, particle characterization & 21 CFR Part 11 audit trails. Hosted on QEEMA
Direct Video Demonstration

CLAIRITY™ Suite - AI Image Analysis Overview

AI-powered pharmaceutical microscopy, particle characterization & 21 CFR Part 11 audit trails.

Request On-Site Trial
CLAIRITY™ SUITE BY IMAGEPROVISION

Pharmaceutical AI Vision & Microscopy Portfolio

11 solutions

CLAIRITY™ PARTICLE — Particle size & shape analysis system 0.5 – 3,000 µm
ImageProVision · CLAIRITY™ PARTICLE System
ImageProVision · Particle Characterization

CLAIRITY™ PARTICLE

Comprehensive Particle Size & Shape Morphology

Advanced digital image analysis platform measuring particle dimensions, circularity, elongation, aspect ratio, and distribution curves for APIs, excipients, and suspensions.

0.5 – 3,000 µm USP <788> / <789> 21 CFR Part 11 Shape Factors
Optical Range:0.5 µm to 3,000 µm (Sub-visible to macro)
Key Metrics:Feret Min/Max, Aspect Ratio, Circularity, Convexity
Regulatory:USP <788>, USP <789>, Ph. Eur. 2.9.19, EP, BP
Camera Sensor:High-Resolution Scientific CMOS (Sony Pregius)
Validation:Complete DQ/IQ/OQ/PQ & GAMP 5 CSV by QEEMA
Explore system & video demo ↗
CLAIRITY™ AUTO — Automated particle characterization system Motorized XY Stage
ImageProVision · CLAIRITY™ AUTO Automated Stage
ImageProVision · Automated Scanning

CLAIRITY™ AUTO

Automated Membrane & Particulate Counting

Automated motorized microscopy workflows for membrane filter scanning, high-throughput particulate matter counting, and regulatory compliance without operator fatigue.

Motorized XY Stage USP <788> Method 2 Multi-Field Tiling Auto Thresholding
Stage Accuracy:0.1 µm step resolution motorized XY scanning
Filter Types:Standard 25 mm & 47 mm membrane filters
Throughput:Scans hundreds of fields in under 5 minutes
Compliance:FDA 21 CFR Part 11, EU Annex 11, USP <788>
Validation:Stage positioning IQ/OQ, optical calibration
Explore system & video demo ↗
CLAIRITY™ NANO — Nanoparticle analysis platform 0.1 – 10 µm Range
ImageProVision · CLAIRITY™ NANO Platform
ImageProVision · Nanotechnology

CLAIRITY™ NANO

Sub-Micron & Nanoparticle Imaging Analysis

Specialized optical image processing for characterizing particles at the sub-micron and nanoscale, vital for nano-suspensions, lipid complexes, and advanced drug delivery.

0.1 – 10 µm Range Colloid Sizing Nano Tracking 21 CFR Part 11
Detection Limit:Down to 0.1 µm with specialized high-NA optics
Sample Types:Liposomes, nano-emulsions, injectable colloids
Standards:ISO 13322-1, FDA Nanotechnology Guidance
Data Integrity:ALCOA+ compliant encrypted database
Validation:Sub-micron graticule calibration protocol
Explore system & video demo ↗
CLAIRITY™ SIA — Static image analysis platform 1.0 – 5,000 µm
ImageProVision · CLAIRITY™ SIA Platform
ImageProVision · Powder Characterization

CLAIRITY™ SIA

Static Image Analysis for Powders & Granules

Dedicated static-image workflows capturing high-resolution still micrographs for API powder morphology, agglomeration analysis, and dry granule size distribution.

1.0 – 5,000 µm Dry Powder Cell ISO 13322-1 Particle Statistics
Measurement Range:1.0 µm to 5,000 µm bulk powder analysis
Dispersion Modes:Dry powder dispersion & wet slide mounting
Parameters:Equivalent circular diameter, convexity, solidity
Output:D10, D50, D90, cumulative & frequency curves
Validation:Traceable stage micrometer calibration kit
Explore system & video demo ↗
CLAIRITY™ THERMAL — Hot stage microscopy software -196°C to +600°C
ImageProVision · CLAIRITY™ THERMAL Module
ImageProVision · Thermal Analysis

CLAIRITY™ THERMAL

Hot Stage Microscopy & Polymorphic Screening

Synchronized optical video and temperature profiling to capture polymorphic phase transitions, desolvation, melting points, and crystallization kinetics in real time.

-196°C to +600°C USP <891> Thermal Phase Transitions Time-Lapse Video
Thermal Compatibility:Couples with Linkam / Instec hot stages
Applications:Polymorphic form screening, solvate desolvation
Capture Modes:Burst thermography & time-lapse synchronized video
Regulatory:USP <891> Thermal Analysis, Ph. Eur. 2.2.34
Audit Trail:Time-stamped temperature-image sync logging
Explore system & video demo ↗
CLAIRITY™ VIA — Visual inspection analysis for parenterals USP <790> / <1790>
ImageProVision · CLAIRITY™ VIA Inspection Station
ImageProVision · Parenteral Inspection

CLAIRITY™ VIA

Automated Visual Inspection for Vials & Ampoules

High-resolution imaging station designed to investigate visible foreign matter, fibers, glass lamellae, and stopper particles in parenteral vials, ampoules, and prefilled syringes.

USP <790> / <1790> Vials & Ampoules Foreign Matter Defect Verification
Containers:Clear & amber glass vials, ampoules, syringes (1–100 ml)
Defects Detected:Glass shards, fibers, rubber fragments, floaters
Illumination:Multi-angle darkfield & polarized illumination
Standards:USP <790> (100% inspection), USP <1790> automated
Validation:Knapp challenge testing & false-reject qualification
Explore system & video demo ↗
CLAIRITY™ SEAM — Capsule seam and seal analysis ±0.005 mm Accuracy
ImageProVision · CLAIRITY™ SEAM System
ImageProVision · Capsule Integrity

CLAIRITY™ SEAM

Precision Capsule Wall Thickness & Seam Quality

Optical measurement software determining capsule seam thickness, dome uniformity, cap-body junction overlap, and sealing band integrity for hard gelatin and HPMC capsules.

±0.005 mm Accuracy Gelatin & HPMC Seam Overlap SPC Statistical QC
Accuracy:±0.005 mm (5 µm) optical dimension measurement
Capsule Sizes:Formats 000, 00, 0, 1, 2, 3, 4, 5 (Gelatin & HPMC)
Defect Checks:Wall thickness variance, seam overlap, pinholes
Reporting:Automated SPC control charts and PDF certificates
Validation:Certified dimensional calibration blocks & IQ/OQ
Explore system & video demo ↗
CLAIRITY™ MICROBE — Automated microbial colony counter <1 Sec / Plate
ImageProVision · CLAIRITY™ MICROBE Counter
ImageProVision · Microbiology QC

CLAIRITY™ MICROBE

Automated Microbial Colony Counting (CFU)

Instantaneous digital colony enumeration for bioburden testing, environmental monitoring plates, and water testing. Eliminates operator counting fatigue and human calculation errors.

<1 Sec / Plate USP <61> / <62> Petri & Spiral Audit Trail Log
Plate Formats:90 mm Petri dishes, 55 mm contact plates, membrane filters
Speed:Instant count (<1 second) with colony splitting algorithms
Standards:USP <61>, USP <62>, ISO 7218 Microbiology
Audit Security:21 CFR Part 11 encrypted raw plate images
Validation:Colony standard plate challenge test & CSV protocol
Explore system & video demo ↗
CLAIRITY™ XCELL — Cell counting and viability assessment Trypan Blue Assay
ImageProVision · CLAIRITY™ XCELL Analyzer
ImageProVision · Bioprocess QC

CLAIRITY™ XCELL

Cell Viability & Concentration Assessment

Image-based cell counting, viability determination, and trypan blue exclusion profiling for cell culture monitoring in vaccine manufacturing, bioreactors, and biotechnology laboratories.

Trypan Blue Assay Viability % 5 – 70 µm Cells Bioprocess Monitoring
Cell Types:Mammalian, insect, stem cells, yeast (5 µm to 70 µm)
Metrics:Total cell count, viable density, % viability, diameter distribution
Analysis Time:Under 15 seconds per multi-chamber sample
Regulatory:USP <1046> Cell Therapy, 21 CFR Part 11 compliant
Validation:Standard bead comparison and hemocytometer cross-check
Explore system & video demo ↗
CLAIRITY™ PROOFCHECK — Automated digital proofreading system Text & Graphics
ImageProVision · CLAIRITY™ PROOFCHECK Suite
ImageProVision · Packaging Quality

CLAIRITY™ PROOFCHECK

Automated Packaging Artwork & Leaflet Proofreading

Digital comparison system catching missing letters, spelling errors, font deviations, barcode defects, and graphical flaws across multilingual packaging leaflets and cartons.

Text & Graphics Barcode & 2D QR Braille Verification Multilingual Arabic/EN
Comparison Modes:Digital-to-Digital PDF, Printed Scan-to-Digital PDF
Defects Caught:Missing accents, font shifts, color hue, text shifts
Code Verification:GS1 1D/2D Barcodes, Data Matrix, Pharmacode, QR
Regulatory:FDA 21 CFR Part 11, EU GMP Annex 11 packaging safety
Validation:Software algorithm IQ/OQ and CSV documentation
Explore system & video demo ↗
CLAIRITY™ MORPHOWIZ — AI-based particle analysis and defect classifier AI Neural Network
ImageProVision · CLAIRITY™ MORPHOWIZ AI Platform
ImageProVision · Deep Learning AI

CLAIRITY™ MORPHOWIZ

AI Neural Network Foreign Particle Classification

Deep learning convolutional neural network (CNN) trained on vast pharma datasets to automatically identify and classify unknown foreign matter (metallic, fiber, glass, rubber, skin).

AI Neural Network >98.5% Accuracy Root Cause CAPA FDA GMLP Compliant
AI Architecture:Deep Convolutional Neural Network (CNN)
Material Classes:Metallic, glass flakes, fibers, hair, elastomer, blister foil
Applications:Rapid root cause analysis for OOS/CAPA investigations
Regulatory:Good Machine Learning Practice (GMLP) for Pharma
Validation:Model verification dossier & algorithm test challenge
Explore system & video demo ↗
INTERACTIVE LAB CONFIGURATOR

CLAIRITY™ AI Solution & Compliance Matcher

Select your pharmaceutical quality control testing application to identify the recommended CLAIRITY™ imaging system, pharmacopeial standards, and certified QEEMA validation protocol.

RECOMMENDED CONFIGURATION

CLAIRITY™ PARTICLE System

Microscopy-based particle dimensions, aspect ratio, circularity, and USP <788>/<789> sizing.

  • Target Standard: USP <788>, USP <789>, Ph. Eur. 2.9.19, BP
  • Detection Range: 0.5 µm to 3,000 µm (Sub-Visible to Macro)
  • Data Integrity Tier: Full FDA 21 CFR Part 11 & EU Annex 11
  • Optics & Hardware: Motorized Precision XY Stage
  • Local Support in Egypt: Turnkey DQ/IQ/OQ/PQ & CSV by QEEMA
WHY PHARMA AUDITORS PREFER CLAIRITY™

Manual QC Microscopy vs. CLAIRITY™ Automated AI Vision

Eliminating analyst fatigue, subjective operator bias, and compliance audit observations in pharmaceutical particle sizing and parenteral inspection.

Evaluation Metric Traditional Manual Microscopy ImageProVision CLAIRITY™ AI Platform
Analysis Speed & Throughput 45–90 minutes per sample slide; analyst eye strain limits daily batch capacity. 2–5 minutes per sample; fully automated multi-field scanning.
Measurement Repeatability High operator variability (15–30% RSD between different analysts). <1.5% RSD; objective pixel-calibrated digital algorithms.
Morphological Characterization 1D Feret diameter only; subjective estimation of circularity and shape. Full 2D/3D metrics: circularity, aspect ratio, convexity, elongation, solidity.
21 CFR Part 11 & Audit Trail Manual logbooks, external paper printouts, vulnerability to ALCOA audit findings. Built-in tamper-proof audit trail, dual electronic signatures, automated audit report.
Local Validation in Egypt Third-party paperwork, delayed vendor support from overseas. Turnkey DQ/IQ/OQ/PQ & CSV execution delivered on-site by QEEMA specialists.
INTERNATIONAL REGULATORY COMPLIANCE

Built For US FDA, WHO & EDA Regulatory Audits

Every ImageProVision system is engineered from the ground up to meet stringent global pharmacopeial standards and data governance frameworks, validated locally in Egypt by QEEMA.

21 CFR Part 11

Cryptographic audit trails, multi-level user permissions, and dual electronic signatures.

USP <788> / <789>

Automated sub-visible particulate counting for sterile parenterals & ophthalmic solutions.

ALCOA+ Data Integrity

Attributable, Legible, Contemporaneous, Original, and Accurate data storage.

Turnkey Local CSV

QEEMA delivers on-site DQ/IQ/OQ/PQ protocols, calibration, and analyst certification in Egypt.

INTEGRATED PHARMACEUTICAL SOLUTIONS THROUGH QEEMA EGYPT

From Laboratory URS to Complete Qualification

01

Define & Select

Technical consultation, optical magnification planning, sample type evaluation, and user requirement specification (URS) alignment.

02

Install & Qualify

On-site delivery, optical calibration, certified DQ, IQ, OQ, and PQ execution tailored to your specific dosage forms.

03

CSV & Lifetime Support

GAMP 5 computerized system validation (CSV), analyst SOP training, annual recalibration, and continuous local support in Egypt.

QEEMA validation services are scoped separately for each laboratory. Explore CSV services ↗

// أسئلة شائعة ودليل الوكالة المعتمدة بمصر // AUTHORIZED PARTNERSHIP & REGULATORY FAQ

ImageProVision in Egypt & MENA
الأسئلة الشائعة وتفاصيل التوريد والاعتماد الصيدلاني

إجابات شاملة لمديري الجودة (QA/QC) والبحث والتطوير (R&D) بمصانع الأدوية حول أجهزة فحص الجزيئات، مطابقة معايير الدساتير العالمية USP <788> / <789>، ونظم التحقق المعتمدة لـ 21 CFR Part 11 في مصر والشرق الأوسط.

من هو الوكيل المعتمد لشركة ImageProVision في مصر والشرق الأوسط؟

شركة قيمة مصر (QEEMA Egypt) هي الشريك الاستراتيجي والوكيل المعتمد لشركة ImageProVision Inc. (Princeton, USA) في جمهورية مصر العربية والوطن العربي. نتولى التوريد الرسمي لكافة أجهزة ومنظومات CLAIRITY™، مع التكفل بتقديم الدعم الفني المحلي المباشر، خدمات الصيانة والمعايرة الدورية، وتنفيذ بروتوكولات التأهيل والتحقق الهندسي الكامل (DQ / IQ / OQ / PQ) بأيدي خبراء استشاريين معتمدين.

ما هي حلول ImageProVision لاختبارات شوائب الحقن طبقاً لـ USP <788> و USP <789>؟

توفر منظومة CLAIRITY™ PARTICLE و CLAIRITY™ AUTO تقنيات متقدمة للرؤية الحاسوبية والذكاء الاصطناعي لفحص وتصنيف الجزيئات والشوائب غير المرئية (Sub-visible Particulate Matter) في محاليل الحقن والقطرات العينية والمستحضرات البيولوجية، بأحجام تبدأ من 1 ميكرون وحتى عدة ملليمترات. تتوافق الأجهزة بالكامل مع متطلبات USP <788> (Injections) و USP <789> (Ophthalmic Solutions) و Ph. Eur. 2.9.19، مع تقديم قياسات دقيقة لشكل وحجم واستطالة واستدارة الجزيئات لتحديد مصدر الشوائب بدقة فائقة.

كيف تضمن أنظمة CLAIRITY الامتثال لقواعد 21 CFR Part 11 وسلامة البيانات (Data Integrity)؟

تم تطوير كافة برمجيات CLAIRITY™ لتتطابق تماماً مع اشتراطات هيئة الغذاء والدواء الأمريكية US FDA 21 CFR Part 11 وملحق EU GMP Annex 11. تشمل الميزات المدمجة: مسار تدقيق إلكتروني محمي غير قابل للتعديل (Tamper-proof Audit Trail)، نظام توقيعات إلكترونية متعدد المستويات، تشفير كامل لقواعد البيانات، إدارة متطورة لأدوار وصلاحيات المستخدمين، وتقارير رقمية مؤمنة ضد التلاعب تضمن اجتياز أصعب تفتيشات هيئة الدواء المصرية (EDA) والمراجعين الدوليين.

ما هي مراحل التأهيل (Validation) التي تقدمها شركة قيمة لعملاء ImageProVision؟

تقدم شركة قيمة خدمة متكاملة للمصانع والمختبرات تشمل:
• إعداد وتدقيق متطلبات المستخدم (URS) ومطابقتها للمواصفات الفنية.
• التثبيت والتركيب الموقعي مع تنفيذ بروتوكولات التأهيل التركيبي والتشغيلي (IQ / OQ).
• تأهيل الأداء (PQ) وتأهيل برمجيات الحاسب الآلي (CSV / GAMP 5).
• تدريب معتمد لفريق العمل المخبري، وتوفير شهادات المعايرة ومصفوفات التتبع الكاملة لمواجهة أي تفتيش تنظيمي.

كيف يمكن طلب استشارة أو تجربة عملية (Live Demo) لأجهزة CLAIRITY في مصر؟

يمكن لشركات الأدوية والمراكز البحثية والمستشفيات في مصر والشرق الأوسط طلب جلسة عرض حي (Live Demonstration) أو تحليل عينات تجريبية من خلال التواصل المباشر مع خبراء شركة قيمة عبر نموذج الاتصال أدناه، أو عبر البريد الإلكتروني المباشر info@qeemaegypt.com، أو الهاتف 201097155572+. يقوم فريقنا المتخصص بزيارتكم أو التنسيق لاختبار عيناتكم الفعلية وإعداد تقرير تحليلي مقارن.

LET’S DISCUSS YOUR PROJECT

The right AI vision technology.
The right validation support.

Tell us about your laboratory or manufacturing inspection requirements. QEEMA will evaluate your sample types, prepare customized URS specifications, and arrange a live technical demonstration.

Official Egyptian Partner Office:

Al Manal Mall, Jordanian Road, 10th of Ramadan City 1, Egypt

info@qeemaegypt.com

+20 109 715 5572